{"product_id":"cleveland-25-gallon-gas-tilting-steam-jacketed-kettle-with-standard-controls","title":"Cleveland 25-Gallon Gas Tilting Steam-Jacketed Kettle with Standard Controls","description":"\u003cp data-start=\"411\" data-end=\"701\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe Cleveland KGL25T is a 25-gallon self-contained gas tilting kettle designed for commercial batch cooking. Its 2\/3 steam-jacketed construction transfers heat across the lower portion of the kettle, while the 90,000 BTU gas-fired heating system delivers 58,500 BTU directly to the product.\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"703\" data-end=\"968\"\u003eStandard solid-state controls provide an operating temperature range of 145°F to 260°F with less than ±1°C temperature variance. The control panel includes a power on\/off control, a 1–10 temperature dial, and LED indicators for the heat cycle and low-water warning.\u003c\/p\u003e\n\u003cp data-start=\"970\" data-end=\"1226\"\u003eThe kettle features a permanently filled 50 PSI steam jacket, automatic electronic spark ignition, a front-mounted pressure\/vacuum gauge, and a self-locking mechanical tilt system. Its support legs include adjustable flanged feet for secure floor mounting.\u003c\/p\u003e\n\u003ch3 data-section-id=\"pm8yra\" data-start=\"1228\" data-end=\"1248\"\u003e\u003cspan role=\"text\"\u003eKey Features\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1250\" data-end=\"2818\"\u003e\n\u003cli data-section-id=\"x7zk2m\" data-start=\"1250\" data-end=\"1281\"\u003e25-gallon \/ 95-liter capacity\u003c\/li\u003e\n\u003cli data-section-id=\"ritg85\" data-start=\"1282\" data-end=\"1324\"\u003eSelf-contained floor-model configuration\u003c\/li\u003e\n\u003cli data-section-id=\"ijzq1r\" data-start=\"1325\" data-end=\"1348\"\u003eTilting kettle design\u003c\/li\u003e\n\u003cli data-section-id=\"1j6qi18\" data-start=\"1349\" data-end=\"1382\"\u003e2\/3 steam-jacketed construction\u003c\/li\u003e\n\u003cli data-section-id=\"1hjdto6\" data-start=\"1383\" data-end=\"1411\"\u003e50 PSI steam-jacket rating\u003c\/li\u003e\n\u003cli data-section-id=\"1o47qgw\" data-start=\"1412\" data-end=\"1449\"\u003e90,000 BTU gas-fired heating system\u003c\/li\u003e\n\u003cli data-section-id=\"iieub0\" data-start=\"1450\" data-end=\"1494\"\u003e58,500 BTU applied directly to the product\u003c\/li\u003e\n\u003cli data-section-id=\"1869ioz\" data-start=\"1495\" data-end=\"1533\"\u003eApproximately 65% heating efficiency\u003c\/li\u003e\n\u003cli data-section-id=\"16asa9x\" data-start=\"1534\" data-end=\"1566\"\u003eStandard natural gas operation\u003c\/li\u003e\n\u003cli data-section-id=\"12zeljr\" data-start=\"1567\" data-end=\"1597\"\u003ePropane gas option available\u003c\/li\u003e\n\u003cli data-section-id=\"lhoei8\" data-start=\"1598\" data-end=\"1632\"\u003eSolid-state temperature controls\u003c\/li\u003e\n\u003cli data-section-id=\"l4y85z\" data-start=\"1633\" data-end=\"1680\"\u003eOperating temperature range of 145°F to 260°F\u003c\/li\u003e\n\u003cli data-section-id=\"1gostsf\" data-start=\"1681\" data-end=\"1718\"\u003eLess than ±1°C temperature variance\u003c\/li\u003e\n\u003cli data-section-id=\"1lak2za\" data-start=\"1719\" data-end=\"1741\"\u003ePower on\/off control\u003c\/li\u003e\n\u003cli data-section-id=\"1gzcvuo\" data-start=\"1742\" data-end=\"1765\"\u003e1–10 temperature dial\u003c\/li\u003e\n\u003cli data-section-id=\"ox87xi\" data-start=\"1766\" data-end=\"1792\"\u003eLED heat-cycle indicator\u003c\/li\u003e\n\u003cli data-section-id=\"clmfnp\" data-start=\"1793\" data-end=\"1826\"\u003eLED low-water warning indicator\u003c\/li\u003e\n\u003cli data-section-id=\"134n53h\" data-start=\"1827\" data-end=\"1858\"\u003eLow-water safety power cutoff\u003c\/li\u003e\n\u003cli data-section-id=\"1t86t6a\" data-start=\"1859\" data-end=\"1892\"\u003ePermanently filled steam jacket\u003c\/li\u003e\n\u003cli data-section-id=\"oc6ogv\" data-start=\"1893\" data-end=\"1943\"\u003eSteam jacket filled with treated distilled water\u003c\/li\u003e\n\u003cli data-section-id=\"1rn3ki2\" data-start=\"1944\" data-end=\"1998\"\u003eJacket does not require routine venting or refilling\u003c\/li\u003e\n\u003cli data-section-id=\"drddwe\" data-start=\"1999\" data-end=\"2036\"\u003eAutomatic electronic spark ignition\u003c\/li\u003e\n\u003cli data-section-id=\"rizlx8\" data-start=\"2037\" data-end=\"2070\"\u003eSupplied gas pressure regulator\u003c\/li\u003e\n\u003cli data-section-id=\"13cb8a9\" data-start=\"2071\" data-end=\"2121\"\u003eFront-mounted splash-proof pressure\/vacuum gauge\u003c\/li\u003e\n\u003cli data-section-id=\"1kgmk2q\" data-start=\"2122\" data-end=\"2170\"\u003eLarge pouring lip for easier product discharge\u003c\/li\u003e\n\u003cli data-section-id=\"51pgtv\" data-start=\"2171\" data-end=\"2218\"\u003eHeavy-duty rolled rim for added reinforcement\u003c\/li\u003e\n\u003cli data-section-id=\"wmlkej\" data-start=\"2219\" data-end=\"2264\"\u003eMechanical tilt system with roller bearings\u003c\/li\u003e\n\u003cli data-section-id=\"1c4ivtz\" data-start=\"2265\" data-end=\"2315\"\u003eCase-hardened self-locking worm-and-segment gear\u003c\/li\u003e\n\u003cli data-section-id=\"1jdl0u8\" data-start=\"2316\" data-end=\"2371\"\u003eType 316 stainless steel kettle and exterior surfaces\u003c\/li\u003e\n\u003cli data-section-id=\"1ppeeak\" data-start=\"2372\" data-end=\"2408\"\u003eNo standard tangent draw-off valve\u003c\/li\u003e\n\u003cli data-section-id=\"5c8umd\" data-start=\"2409\" data-end=\"2434\"\u003eAdjustable support feet\u003c\/li\u003e\n\u003cli data-section-id=\"1yd8aug\" data-start=\"2435\" data-end=\"2467\"\u003eFlanged feet for floor bolting\u003c\/li\u003e\n\u003cli data-section-id=\"iuha86\" data-start=\"2468\" data-end=\"2522\"\u003eRequires a gas connection and 115V electrical outlet\u003c\/li\u003e\n\u003cli data-section-id=\"1goj4la\" data-start=\"2523\" data-end=\"2563\"\u003eSupplied with electrical cord and plug\u003c\/li\u003e\n\u003cli data-section-id=\"1uvn63\" data-start=\"2564\" data-end=\"2618\"\u003eTypical approvals include AGA, CSA, CE, NSF and ASME\u003c\/li\u003e\n\u003cli data-section-id=\"b6f6le\" data-start=\"2619\" data-end=\"2657\"\u003eOptional easyDial controls available\u003c\/li\u003e\n\u003cli data-section-id=\"1u743cf\" data-start=\"2658\" data-end=\"2712\"\u003eOptional spring-assisted or lift-off cover available\u003c\/li\u003e\n\u003cli data-section-id=\"1wkdhsy\" data-start=\"2713\" data-end=\"2763\"\u003eOptional 2-inch tangent draw-off valve available\u003c\/li\u003e\n\u003cli data-section-id=\"1j4gkbp\" data-start=\"2764\" data-end=\"2818\"\u003eOptional hot-and-cold or cold-water faucet available\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"2l0mzs\" data-start=\"2820\" data-end=\"2842\"\u003e\u003cspan role=\"text\"\u003eSpecifications\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2844\" data-end=\"4238\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2844\" data-end=\"2871\"\u003e\n\u003ctr data-start=\"2844\" data-end=\"2871\"\u003e\n\u003cth data-start=\"2844\" data-end=\"2860\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"2860\" data-end=\"2871\" data-col-size=\"md\" class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2882\" data-end=\"4238\"\u003e\n\u003ctr data-start=\"2882\" data-end=\"2919\"\u003e\n\u003ctd data-start=\"2882\" data-end=\"2893\" data-col-size=\"sm\"\u003eCapacity\u003c\/td\u003e\n\u003ctd data-start=\"2893\" data-end=\"2919\" data-col-size=\"md\"\u003e25 gallons \/ 95 liters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2920\" data-end=\"2960\"\u003e\n\u003ctd data-start=\"2920\" data-end=\"2944\" data-col-size=\"sm\"\u003eSteam Jacket Coverage\u003c\/td\u003e\n\u003ctd data-start=\"2944\" data-end=\"2960\" data-col-size=\"md\"\u003e2\/3 jacketed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2961\" data-end=\"2993\"\u003e\n\u003ctd data-start=\"2961\" data-end=\"2983\" data-col-size=\"sm\"\u003eSteam Jacket Rating\u003c\/td\u003e\n\u003ctd data-start=\"2983\" data-end=\"2993\" data-col-size=\"md\"\u003e50 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2994\" data-end=\"3029\"\u003e\n\u003ctd data-start=\"2994\" data-end=\"3006\" data-col-size=\"sm\"\u003eGas Input\u003c\/td\u003e\n\u003ctd data-start=\"3006\" data-end=\"3029\" data-col-size=\"md\"\u003e90,000 BTU per hour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3030\" data-end=\"3079\"\u003e\n\u003ctd data-start=\"3030\" data-end=\"3056\" data-col-size=\"sm\"\u003eHeat Applied to Product\u003c\/td\u003e\n\u003ctd data-start=\"3056\" data-end=\"3079\" data-col-size=\"md\"\u003e58,500 BTU per hour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3080\" data-end=\"3122\"\u003e\n\u003ctd data-start=\"3080\" data-end=\"3101\" data-col-size=\"sm\"\u003eHeating Efficiency\u003c\/td\u003e\n\u003ctd data-start=\"3101\" data-end=\"3122\" data-col-size=\"md\"\u003eApproximately 65%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3123\" data-end=\"3154\"\u003e\n\u003ctd data-start=\"3123\" data-end=\"3139\" data-col-size=\"sm\"\u003eStandard Fuel\u003c\/td\u003e\n\u003ctd data-start=\"3139\" data-end=\"3154\" data-col-size=\"md\"\u003eNatural gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3155\" data-end=\"3186\"\u003e\n\u003ctd data-start=\"3155\" data-end=\"3171\" data-col-size=\"sm\"\u003eOptional Fuel\u003c\/td\u003e\n\u003ctd data-start=\"3171\" data-end=\"3186\" data-col-size=\"md\"\u003ePropane gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3187\" data-end=\"3245\"\u003e\n\u003ctd data-start=\"3187\" data-end=\"3217\" data-col-size=\"sm\"\u003eOperating Temperature Range\u003c\/td\u003e\n\u003ctd data-start=\"3217\" data-end=\"3245\" data-col-size=\"md\"\u003e145°F–260°F \/ 63°C–127°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3246\" data-end=\"3296\"\u003e\n\u003ctd data-start=\"3246\" data-end=\"3269\" data-col-size=\"sm\"\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"3269\" data-end=\"3296\" data-col-size=\"md\"\u003eLess than ±1°C variance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3297\" data-end=\"3341\"\u003e\n\u003ctd data-start=\"3297\" data-end=\"3308\" data-col-size=\"sm\"\u003eControls\u003c\/td\u003e\n\u003ctd data-start=\"3308\" data-end=\"3341\" data-col-size=\"md\"\u003eSolid-state standard controls\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3342\" data-end=\"3388\"\u003e\n\u003ctd data-start=\"3342\" data-end=\"3367\" data-col-size=\"sm\"\u003eTemperature Adjustment\u003c\/td\u003e\n\u003ctd data-start=\"3367\" data-end=\"3388\" data-col-size=\"md\"\u003e1–10 dial setting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3389\" data-end=\"3451\"\u003e\n\u003ctd data-start=\"3389\" data-end=\"3410\" data-col-size=\"sm\"\u003eControl Indicators\u003c\/td\u003e\n\u003ctd data-start=\"3410\" data-end=\"3451\" data-col-size=\"md\"\u003eHeat cycle and low-water warning LEDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3452\" data-end=\"3502\"\u003e\n\u003ctd data-start=\"3452\" data-end=\"3463\" data-col-size=\"sm\"\u003eIgnition\u003c\/td\u003e\n\u003ctd data-start=\"3463\" data-end=\"3502\" data-col-size=\"md\"\u003eAutomatic electronic spark ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3503\" data-end=\"3532\"\u003e\n\u003ctd data-start=\"3503\" data-end=\"3520\" data-col-size=\"sm\"\u003eGas Connection\u003c\/td\u003e\n\u003ctd data-start=\"3520\" data-end=\"3532\" data-col-size=\"md\"\u003e3\/4\" NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3533\" data-end=\"3576\"\u003e\n\u003ctd data-start=\"3533\" data-end=\"3563\" data-col-size=\"sm\"\u003eNatural Gas Supply Pressure\u003c\/td\u003e\n\u003ctd data-start=\"3563\" data-end=\"3576\" data-col-size=\"md\"\u003e4.2\" W.C.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3577\" data-end=\"3635\"\u003e\n\u003ctd data-start=\"3577\" data-end=\"3603\" data-col-size=\"sm\"\u003eElectrical Requirements\u003c\/td\u003e\n\u003ctd data-start=\"3603\" data-end=\"3635\" data-col-size=\"md\"\u003e115–120V, 60Hz, single phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3636\" data-end=\"3677\"\u003e\n\u003ctd data-start=\"3636\" data-end=\"3660\" data-col-size=\"sm\"\u003eElectrical Connection\u003c\/td\u003e\n\u003ctd data-start=\"3660\" data-end=\"3677\" data-col-size=\"md\"\u003eCord and plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3678\" data-end=\"3714\"\u003e\n\u003ctd data-start=\"3678\" data-end=\"3705\" data-col-size=\"sm\"\u003eKettle Interior Diameter\u003c\/td\u003e\n\u003ctd data-start=\"3705\" data-end=\"3714\" data-col-size=\"md\"\u003e21 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3715\" data-end=\"3752\"\u003e\n\u003ctd data-start=\"3715\" data-end=\"3739\" data-col-size=\"sm\"\u003eKettle Interior Depth\u003c\/td\u003e\n\u003ctd data-start=\"3739\" data-end=\"3752\" data-col-size=\"md\"\u003e20-1\/2 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3753\" data-end=\"3779\"\u003e\n\u003ctd data-start=\"3753\" data-end=\"3770\" data-col-size=\"sm\"\u003eOverall Height\u003c\/td\u003e\n\u003ctd data-start=\"3770\" data-end=\"3779\" data-col-size=\"md\"\u003e50 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3780\" data-end=\"3817\"\u003e\n\u003ctd data-start=\"3780\" data-end=\"3798\" data-col-size=\"sm\"\u003eShipping Weight\u003c\/td\u003e\n\u003ctd data-start=\"3798\" data-end=\"3817\" data-col-size=\"md\"\u003e320 lb \/ 144 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3818\" data-end=\"3881\"\u003e\n\u003ctd data-start=\"3818\" data-end=\"3841\" data-col-size=\"sm\"\u003eRight-Side Clearance\u003c\/td\u003e\n\u003ctd data-start=\"3841\" data-end=\"3881\" data-col-size=\"md\"\u003e0 in; allow 12 in for service access\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3882\" data-end=\"3912\"\u003e\n\u003ctd data-start=\"3882\" data-end=\"3904\" data-col-size=\"sm\"\u003eLeft-Side Clearance\u003c\/td\u003e\n\u003ctd data-start=\"3904\" data-end=\"3912\" data-col-size=\"md\"\u003e0 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3913\" data-end=\"3938\"\u003e\n\u003ctd data-start=\"3913\" data-end=\"3930\" data-col-size=\"sm\"\u003eRear Clearance\u003c\/td\u003e\n\u003ctd data-start=\"3930\" data-end=\"3938\" data-col-size=\"md\"\u003e4 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3939\" data-end=\"3997\"\u003e\n\u003ctd data-start=\"3939\" data-end=\"3954\" data-col-size=\"sm\"\u003eConstruction\u003c\/td\u003e\n\u003ctd data-start=\"3954\" data-end=\"3997\" data-col-size=\"md\"\u003eType 316 stainless steel with #4 finish\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3998\" data-end=\"4074\"\u003e\n\u003ctd data-start=\"3998\" data-end=\"4015\" data-col-size=\"sm\"\u003eTilt Mechanism\u003c\/td\u003e\n\u003ctd data-start=\"4015\" data-end=\"4074\" data-col-size=\"md\"\u003eRoller bearings with self-locking worm-and-segment gear\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4075\" data-end=\"4131\"\u003e\n\u003ctd data-start=\"4075\" data-end=\"4092\" data-col-size=\"sm\"\u003ePressure Gauge\u003c\/td\u003e\n\u003ctd data-start=\"4092\" data-end=\"4131\" data-col-size=\"md\"\u003eFront-mounted pressure\/vacuum gauge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4132\" data-end=\"4187\"\u003e\n\u003ctd data-start=\"4132\" data-end=\"4142\" data-col-size=\"sm\"\u003eSupport\u003c\/td\u003e\n\u003ctd data-start=\"4142\" data-end=\"4187\" data-col-size=\"md\"\u003eAdjustable flanged feet for floor bolting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4188\" data-end=\"4238\"\u003e\n\u003ctd data-start=\"4188\" data-end=\"4208\" data-col-size=\"sm\"\u003eTypical Approvals\u003c\/td\u003e\n\u003ctd data-start=\"4208\" data-end=\"4238\" data-col-size=\"md\"\u003eAGA, CSA, CE, NSF and ASME\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003e\u003c\/h3\u003e\n\u003ch3\u003eGallery\u003c\/h3\u003e\n\u003cp\u003e\u003cvideo style=\"width: 100%; height: auto; display: block;\" controls=\"controls\" playsinline=\"\" loop=\"loop\" muted=\"\" autoplay=\"autoplay\"\u003e\n  \u003csource type=\"video\/mp4\" src=\"https:\/\/cdn.shopify.com\/videos\/c\/o\/v\/4726d6caac9f4ea18fe2e3768edc9cad.mp4\"\u003e\n  Your browser does not support the video tag.\n\u003c\/source\u003e\u003c\/video\u003e\u003c\/p\u003e\n\u003ch3\u003eProduct Support\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0718\/6084\/6771\/files\/KGL-KGL-T-40-UP-Operator-Manual-1.pdf?v=1784619147\"\u003eOwner's Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0718\/6084\/6771\/files\/Cleveland-KGL25T.SpecSheet.pdf?v=1784619163\"\u003eSpec Sheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0718\/6084\/6771\/files\/109-24CEA1022083_warranty.pdf?v=1784616211\"\u003eWarranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Cleveland","offers":[{"title":"Default Title","offer_id":45706261364915,"sku":"KGL25T","price":35502.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0718\/6084\/6771\/files\/Untitleddesign_10.png?v=1784619024","url":"https:\/\/servicesupplydepot.com\/products\/cleveland-25-gallon-gas-tilting-steam-jacketed-kettle-with-standard-controls","provider":"Service Supply Depot","version":"1.0","type":"link"}